Power Plant Generator Replacement Parts | GE Gas Power

2022-09-23 20:36:19 By : Mr. Rain tan

Register today to learn how to achieve lower turndown and reduce maintenance costs with GE’s latest flexibility solution—a variant of the Dry Low NOx (DLN) 2.6+ combustion system that adds Axial Fuel Staging (AFS) technology for further turndown capability.

Today’s peak generation environment and supply chain disruptions are making it harder than ever to keep your HRSG running reliably, efficiently, and affordably. What can you do to mitigate these challenges today and tomorrow?

Higher efficiency leads to lower costs. Learn how our aeroderivative turbines offer many advantages over a reciprocal engine, such as reliability and savings instead of maintenance and downtime.

Want to learn more about how one company was able to expand its hydrogen capabilities? Join us for our latest webinar featuring Dr. Jeffrey Goldmeer and special guests from Long Ridge Energy.

Learn how the generator “bubble” from the early ‘90s and the projected power demands of the future are making planning ahead more important than ever, especially when it comes to your generator maintenance.

Join our webinar and Q&A hosted by our FieldCore CEO Amir Hafzalla where we’ll discuss lessons learned, season highlights and new innovative technologies.

As a plant manager, can you continue to reduce emissions and maintain profitability and reliability? Join our webinar with Jay Bryant to see how you can get the most out of your 7E.

Our scalable, site-ready turbines can address energy gaps and yield huge value for municipalities and co-ops. Learn how GE’s gas power technology solutions can benefit smaller power producers.

Operators and plant managers are experiencing rapid change as the evolving energy landscape impacts their power plants' operating profiles. The ability to adapt and be flexible is key to remaining relevant.

Or start with a popular search:

These days, we're all trying to do more with less, but GE can help. Our upgrades and modernizations can help you get more from your existing assets. Discover the possibilities with our interactive upgrades selector.

Register today to learn how to achieve lower turndown and reduce maintenance costs with GE’s latest flexibility solution—a variant of the Dry Low NOx (DLN) 2.6+ combustion system that adds Axial Fuel Staging (AFS) technology for further turndown capability.

Download the latest GE Gas Power catalog to explore our latest products and services, and discover our extensive experience across a broad spectrum of applications and customers.

See how GE Gas Power is helping to build a world that works.

Listen as Dr. Jeffrey Goldmeer and Brian Gutknecht set the stage for the exciting conversations to come in this season. With topics ranging from transportation and buildings to agriculture and education, there are conversations in this next season that you don't want to miss!

With access to cost-effective gas generator parts engineered to the current standards of GE as an OEM, you can shorten generator maintenance outages. Our expert teams and efficient supply chain mean gas generator parts are in your hands when you need them, also helping you to stretch your generator’s useful life span.

Work together with GE to create the best spare gas generator part strategy for your installed generator assets. With planning, you can lower power plant generator downtime in case of major component failure and address any findings during planned inspections so that they can be fixed before the end of the outage. Strategic spares can be mutualized between identical assets.

Typical strategic spare generator parts include:

Having the right power plant generator parts on hand before the beginning of an outage is vital for on-time execution. Your outage generator parts will have to support the open/close mechanical activities as well as the most common electrical repairs.

The parts needed to support open/close mechanical activities include:

The parts needed to support the most common electrical repairs are:

Auxiliary systems upgrades can provide full compliance with today’s safety regulations for power plant generators.

From generator assessments to identifying generator upgrade potentials, through partial modernizations, to replacements of complete systems, we address parts obsolescence, safety regulations, redundancy, or reliability requirements.

This retrofit kit is engineered to prevent reoccurrence of edge wear and desensitize the bearing to causes of misalignment such as foundation settling, thermal distortion, and cold-to-hot-to-cold growth mismatch, which could lead to elevated bearing metal temperatures and bearing damage in generators.

The improved hydrogen seal ring is engineered with a mechanical stop to limit seal ring movement during transient seal oil pressures and restore normal oil flow path more efficiently, reducing the risk of significant seal oil ingress into the generator.

Newly engineered to improve the ease of brush and spring replacement, the enhanced generator collector brush holder increases brush life, decreases the time required for brush change-out, and reduces the risk of collector flashovers.

If your plant was engineered for base load and is now load cycling, supplying reactive power or starting and stopping, the reliability of your generator can be increased by implementing a generator flexibilization package.

GE Gas Power engineers cleaner, more accessible energy that communities depend on to power growth and prosperity.

See how GE Gas Power is helping to build a world that works.